Electricity distribution managers are continuously under pressure to expand their grids to cope with load growth and properly supply their consumers. To achieve these objectives, it is necessary to provide an acceptable climate for the entry of solar resources and innovative operating practices. This work focuses on a study the impact of the insertion of photovoltaic energy into the low voltage distribution grid. We have shown the impact of weather conditions on the power injected into the grid, the impact of using a single-phase inverter with a TT-neutral regime, the flow of active and reactive bidirectional power to the point of common coupling PCC, and the impact of a grid connected photovoltaic system under different weather conditions and load types. This study was carried out using the Matlab Simulink environment for modeling and simulation of a single-phase system with a 3,5kW transformer inverter and the results show the impact of PV system integration on the overall and individual harmonic level of voltage and current considering several scenarios (variable solar irradiation, variable types of loads),the presence of filters such as the inductor and the capacitor in series or in parallel plays very important role on the improvement in the disturbance of the quality of the current and the tension.
1. Widen, J., Wäckelgård, E., Paatero, J., Lund, P. (2010). Impacts of distributed photovoltaics on network voltages: Stochastic simulations of three Swedish low-voltage distribution grids. Electric power systems research, vol. 80, pp. 1562-1571, doi:10.1016/j.epsr.2010.07.007
2. Bollen och, M., Fainan, H. (2011). Integration of Distributed Generation in the Power System, Hoboken, New Jersey: John Wiley and Sons, Inc.
3. Lecture no.8 in, “SPPT (part 1 and 2),” Chalmers University of Technology, 2014.
4. Madjid, J., MRizwan, D., Kothari, T and Fracis Group. (2017). Grid Integration of Solar Photovoltaic Systems. 1st Edition, Boca Raton, pages 272. https://doi.org/10.1201/9781315156347
5. Boulahchiche, S., Semaoui, S., Bouchakour,S., Makhloufi,S and Rezagui, A and Abdeladim, K A. (2017). Experimental Harmonic Analysis of Three Single-Phase PV Inverters Connected at Low Voltage Network, Conference: 2017 Third International Conference on Electrical Engineering and Control Applications ICEECA’17, November, 21-22, Constantine, Algeria.
6. Abdalla, Y., Mohammed, F., Mohammed, I. and Mamoun, Y. (2017). Grid connected Photovoltaic system, Communication, Control, Computing and Electronics Engineering (ICCCCEE), 2017 International Conference, 16-18 Jan. doi: 10.1007/978-981-15-5444-5_13
7. Ramadan J. Mustafa , Mohamed R. Gomaa , Mujahed Al-Dhaifallah , and Hegazy Rezk . (2020). Environmental Impacts on the Performance of Solar Photovoltaic Systems, Sustainability 2020, 12, 608. https://doi.org/10.3390/su12020608
8. Batool, M., Islam, S., Shahnia, F. (2016). Stochastic Modeling of the Output Power of Photovoltaic Generators in Various Weather Conditions. Australasian Universities Power Engineering Conference. AUPEC 2016. DOI: 10.1109/AUPEC.2016.7749382
9. Arangarajan Vinayagam and all. (2019). Harmonics assessment and mitigation in a photovoltaic integrated network. Sustainable Energy, Grids and Networks, 2019. https://doi.org/10.1016/j.segan.2019.100264
10. Verma, A.K., Singh, B. (2018). Harmonics and reactive current detection of a gridinterfaced PV generation in a distribution system. IEEE Trans. Ind. Appl. Vol 2, no 1, 4786–4794. doi: 10.48175/IJARSCT-2257
11. M. Karimi, et al. (2016). Photovoltaic penetration issues and impacts in distribution network. –A review, ,pp 594–605. doi: 10.1016/j.rser.2015.08.042
12. Chidurala A., Saha T., Mithulananthan N. (2015). Harmonic characterization of grid connected PV systems & validation with field measurements. 2015 IEEE Power & Energy Society General Meeting, Denver, CO, USA, 2015, pp. 1-5, doi: 10.1109/PESGM.2015.7286198
13. Hossain, M.J., et al. (2017). Overview of AC microgrid controls with inverterinterfaced generations. Energies 2017,10(9), 1300. https://doi.org/10.3390/en10091300
14. Anurangi, R., Rodrigo, A.S., Jayatunga, U. (2017). Effects of high levels of harmonic penetration in distribution networks with photovoltaic inverters. Industrial and Information Systems, ICIIS, 2017 IEEE International Conference on, IEEE, 2017. doi:10.1109/ICIINFS.2017.8300335
15. Islam, M. and Mekhilef, Saad and Hasan, M. (2015). Single phase transformerless inverter topologies for grid-tied photovoltaic system: A review. Renewable and Sustainable Energy Reviews, 45. pp. 69-86. ISSN 1364-0321, doi: https://doi.org/10.1016/j.rser.2015.01.009.
16. Gregorio Romero Rey and Luisa Martinez Muneta. Electrical Generation Distribution Systems And Power Quality Disturbances. 2nd Edition 2016. https://www.intechopen.com/books/919
17. Adel, A., Elbaset, M., Hassan, S. (2017). Design and Power Quality Improvement of Photovoltaic Power System, Springer 2017, pages 156. https://fr.scribd.com/document/350340033